Abstract: In order to solve the problem that liquid water accumulates at the corner and end of the flow channel of the PEMFC cathode flow channel in the serpentine flow field, a three-dimensional steady-state non-isothermal serpentine flow field PEMFC model with sub-channel was established by using the fluid dynamics software FLUENT. The effects of sub-channel inlet positions and flow rates on the performance of PEMFC were analyzed when the total amount of oxygen was kept constant. The results show that the sub-channel design can significantly improve the water management and mass transfer capacity of PEMFC, and the performance is optimal when the sub-channel inlet positions is 10 % and the flow rates is 70 %, and the maximum power density is 21.1 % higher than the traditional design.
张可涵, 田爱华, 张福城, 张新峰, 张振东. 分流进气对蛇形流场PEMFC性能影响的研究[J]. 吉林化工学院学报, 2025, 42(9): 31-40.
ZHANG Kehan, TIAN Aihua, ZHANG Fucheng, ZHANG Xinfeng, ZHANG Zhendong. Study of the Effect of Sub-channel Design on the Performance of PEMFC with Serpentine Flow Field. Journal of Jilin Institute of Chemical Technology, 2025, 42(9): 31-40.