Hypochlorite (ClO-), as an effective component of disinfectant and bleach, is commonly used in human production and life.The use of disinfectant containing hypochlorite in a small confined space has certain safety risks. At the same time, ClO-participates in a number of life activities of human body in the body. Excessive ClO- in the body will cause great harm to the immune system of human body and induce a variety of diseases.Therefore, it is necessary to detect ClO- .In this paper, a cadmium sulfide quantum dot fluorescent probe was synthesized by one-pot method using polyethylenimine as the ligand to detect ClO-. The results show that the probe has high selectivity and anti-interference ability in ClO- recognition, and the detection range is 0~40 nmol/L, and the detection limit is 0.5 nmol/L.
尹建行, 谭乃迪.
聚合物包覆的硫化镉量子点的制备及其在次氯酸根检测中的应用
[J]. 吉林化工学院学报, 2020, 37(5): 11-15.
YIN Jianhang, TAN Naidi.
Preparation of cadmium sulfide quantum dot and its application in the detection of hypochlorite
. Journal of Jilin Institute of Chemical Technology, 2020, 37(5): 11-15.